<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>EN 50618 &#8211; R R Kabel Limited</title>
	<atom:link href="https://www.rrkabel.com/products-categories/en-50618/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.rrkabel.com/products-categories/en-50618/</link>
	<description></description>
	<lastBuildDate>Sat, 20 Dec 2025 10:52:55 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://www.rrkabel.com/wp-content/uploads/2023/04/cropped-rr-favicon-32x32.png</url>
	<title>EN 50618 &#8211; R R Kabel Limited</title>
	<link>https://www.rrkabel.com/products-categories/en-50618/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Solar Cable &#8211; EN 50618</title>
		<link>https://www.rrkabel.com/products/solar-cable-en-50618/</link>
		
		<dc:creator><![CDATA[rr-kabel]]></dc:creator>
		<pubDate>Thu, 20 Jul 2023 09:12:04 +0000</pubDate>
				<guid isPermaLink="false">https://www.rrkabel.com/?post_type=products&#038;p=3882</guid>

					<description><![CDATA[<p>The post <a href="https://www.rrkabel.com/products/solar-cable-en-50618/">Solar Cable &#8211; EN 50618</a> appeared first on <a href="https://www.rrkabel.com">R R Kabel Limited</a>.</p>
]]></description>
										<content:encoded><![CDATA[<!-- Images , certification Info and Button Links -->

<section class="cable-detail-main">
    <div class="cable-title-otr">
        <div class="row">
            <div class="col-md-6">
                <div class="cable-title">
                    <h1 class="w-md caps" style="font-size: 32px; line-height: 40px; color: #ee7911;">
                        Solar Cable &#8211; EN 50618                    </h1>
                </div>
            </div>
                        <div class="col-md-6">
                <ul class="cable-category">
                                            <li class="w-md p-reg">REACH</li>
                                            <li class="w-md p-reg">RoHS</li>
                                            <li class="w-md p-reg">CE</li>
                                    </ul>
            </div>
        </div>
    </div>
    <div class="cable-images-otr">
        <div class="row">
            <div class="col-lg-5">
                                    <div class="cable-preview-img">
                        <img decoding="async" src="https://www.rrkabel.com/wp-content/uploads/2023/07/Wire-71.png" alt="Solar Cable" loading="lazy">
                    </div>
                            </div>

            <div class="col-lg-3">
                            </div>

            <div class="col-lg-4">
                                    <div class="cable-preview-img cross-section-img">
                        <img decoding="async" src="https://www.rrkabel.com/wp-content/uploads/2023/07/Cross-71.svg" alt="Solar Cable Cross" loading="lazy">
                    </div>
                            </div>
        </div>
    </div>


    <!-- <div class="cable-options 1">
         <a href="#" class="threesixty-view">
            <img decoding="async" src="/wp-content/uploads/2023/06/360-cam.svg" alt="360-cam" loading="lazy">
        </a>  -->

    <!-- Global Links & individual link for page wise  -->
    <!-- blocks/rr_k_certification_info_template.php -->
    
    <div class="cable-options 123 3882 ">
                    <a href="https://www.rrkabel.com/enquiry/" class="common-btn caps enquire-now-btn p-md w-md" target="_self">
                Enquiry Now                <img decoding="async" src="https://www.rrkabel.com/wp-content/uploads/2023/06/arrow-down.svg" alt="arrow" loading="lazy">
            </a>
        
                    <a href="https://www.rrkabel.com/wp-content/uploads/2023/08/12.-Application-Based-Cables_Single-page.pdf" class="common-btn caps  p-md w-md" target="_blank">
                Brochure                <img decoding="async" src="https://www.rrkabel.com/wp-content/uploads/2023/06/arrow-down.svg" alt="arrow" loading="lazy">
            </a>

        
                    <a href="https://www.rrkabel.com/price-list/" class="common-btn caps  p-md w-md" target="_blank">
                Price List                <img decoding="async" src="https://www.rrkabel.com/wp-content/uploads/2023/06/arrow-down.svg" alt="arrow" loading="lazy">
            </a>
        
                <a href="https://www.rrkabel.com/wp-content/uploads/2023/08/SOLAR-CABLE.pdf" class="common-btn caps dop-btn p-md w-md" target="_blank">
            <span>
                <img decoding="async" src="https://www.rrkabel.com/wp-content/uploads/2023/08/dop-download-btn.svg" alt="CPR" loading="lazy">
            </span>
            Download DOP*        </a>
            </div>
    
</section>


<section class="single-cable-detail">
    <p class="p-title p-md w-md">
        Application    </p>
    <p class="p-desc p-md w-reg">Solar cables are intented for use in photovoltaic power supply systems and similar applications as free hanging, movable, fixed installation and buried in ground in constructional covered systems. The cables can be used indoor, outdoor, in hazard explosion areas, in
industry and agriculture. They are suitable for applications in equipment with protective insulation (protecting Class 2).</p>
</section>

<section class="single-cable-detail">
            <p class="p-title p-md w-md">
                Standard            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md"></span>
                EN 50618:2015.            </p>
            </section>

<section class="single-cable-detail">
            <p class="p-title p-md w-md">
                Thermal parameters            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Max. Permissible Ambient Temperature:</span>
                +90°C (stationary and in motion )            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Max. Permissible Operating Temperature of The Conductor:</span>
                +120°C, Interpretation according to IEC 60216 : permanent temperature.            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md"></span>
                120°C for 20,000 h ( = 2.3 years ), at max. 90°C permanent temperature ( = 30 years ).            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Short &#8211; Circuit Temperature:</span>
                250°C referring to a period of 5 sec.            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Damp &#8211; Heat Test:</span>
                According to EN 60068 &#8211; 2 &#8211; 78. 1,000h at 90°C and 85% humidity.            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Min. Permissible Ambient Temperature:</span>
                -40°C (stationary and in motion)            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Resistance to Cold:</span>
                Bending test at low temperature according to DIN EN 60811 &#8211; 1 &#8211; 4, Impact test similar to DIN EN 50305.            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Minimum Bending Radius:</span>
                Fixed Installation approx. 4 x cable Ø            </p>
            </section>

<section class="single-cable-detail">
            <p class="p-title p-md w-md">
                Electrical Parameters            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Voltage Rating:</span>
                AC 0.6 / 1.0 kV            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Max. PV &#8211; System Voltage:</span>
                DC up to 2.0 kV possible            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Max. Permissible Operating Voltage in AC Systems:</span>
                 0.7 / 1.2 kV            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Max. Permissible Operating Voltage in DC Systems:</span>
                0.9 / 1.8 kV            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Test Voltage:</span>
                AC 6.5 kV / DC 15 kV (15 min.)            </p>
            </section>

<section class="single-cable-detail">
            <p class="p-title p-md w-md">
                Mechanical Parameters            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Tensile Load:</span>
                15 N / mm² in operation. 50 N/mm² during installation            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Shrinkage Test :</span>
                According to EN 60811 &#8211; 1 &#8211; 3            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Shore-Hardness:</span>
                85 shore A according to DIN EN 53505            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Pressure Test at High Temperature:</span>
                According to EN 60811 &#8211; 3 &#8211; 1            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Dynamic Penetration Test :</span>
                According to requirements for cables for PV systems, DKE / VDE 411.2.3            </p>
            </section>

<section class="single-cable-detail">
            <p class="p-title p-md w-md">
                Chemical Parameters            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">AD7 and AD8 compliant:</span>
                AD7 and AD8 compliant for water immersion and water submersion applications            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Mineral Oil Resistance:</span>
                24h, 100°C according to DIN VDE 0473 &#8211; 811 &#8211; 2 &#8211; 1, DIN EN 60811-2-1            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Acid and Alkaline Resistance:</span>
                According to EN 60811-2-1            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md"></span>
                7 days, 23°C (N-Oxalic Acid, N-Sodium Hydroxide)            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Ammonia Resistance:</span>
                30 days in saturated ammonia atmosphere (internal testing)            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Weather Resistance:</span>
                 Ozone resistance according to DIN EN 50396 test Type B, HD 22.2 test Type B UV &#8211; resistance according to UL 1581 (Xenon &#8211; Test), ISO 4892 &#8211; 2 (Method A) and HD 506/A1-2.4.20            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md"></span>
                Absorption of water (gravimetric) according to DIN VDE 0473-811-1-3, DIN EN 60811 &#8211; 1 &#8211; 3.            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Behavior in Case of Fire:</span>
                 Flame propagation.            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md"></span>
                Single cable according to DIN VDE 0482 Part 332 &#8211; 1 &#8211; 2, DIN EN 60332 &#8211; 1 &#8211; 2.            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md"></span>
                Multiple cable according to DIN VDE 0482 Part 266 &#8211; 2 &#8211; 5, DIN EN 50305 &#8211; 9.            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md"></span>
                Low smoke emission according to DIN VDE 0482 Part 268 &#8211; 2.            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md"></span>
                DIN EN 50268-2 (light transmittance > 70% ).            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md"></span>
                Corrosivity according to DIN EN 50267 &#8211; 2 &#8211; 2.            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md"></span>
                Toxicity according to DIN EN 50305, ITC &#8211; index < 3.            </p>
            </section>

<section class="single-cable-detail">
            <p class="p-title p-md w-md">
                Cable Construction            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Conductor:</span>
                Fine Wire Tinned Copper Conductor according to BS EN 60228:2005 cl. 5.            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Insulation:</span>
                UV resistant, cross linkable, halogen free, flame retardant compound for core insulation.            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Core Identification :</span>
                Red, black or natural            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Sheath:</span>
                UV resistant, cross linkable, halogen free, flame retardant compound for Sheath over insulation.            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md">Cable Colour:</span>
                Red, Black, Black with red strip            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md"></span>
                            </p>
                        <p class="p-desc p-md w-reg">
                <span class="w-md"></span>
                Please complete the part numbers for these cables by adding the suffix (in place of &#8216;xx&#8217;) for the insulation colour required as per the list: 02 &#8211; black, 03 &#8211; red, 13 &#8211; natural.            </p>
            </section>

<section class="single-cable-detail">
    <p class="p-title p-md w-md">
        Cable Design Parameters    </p>

    <div class="table-responsive">
     
<table id="tablepress-243" class="tablepress tablepress-id-243 tbody-has-connected-cells">
<tbody>
<tr class="row-1">
	<td rowspan="2" class="column-1"><span>Part Number</span></td><td rowspan="2" class="column-2"><span>Nominal Cross<br />
Sectional Area (Sq. mm)</span></td><td rowspan="2" class="column-3"><span>Insulation Thickness <br />
(mm)</span></td><td rowspan="2" class="column-4"><span>Outer sheath<br />
Thickness<br />
(mm)<br />
</span></td><td rowspan="2" class="column-5"><span>Approx. Cable<br />
Diameter (mm)<br />
as per EN 50618<br />
</span></td><td colspan="3" class="column-6"><span>Current carrying capacity according to method of<br />
installation<br />
</span></td><td rowspan="2" class="column-9"><span>Max. Conductor<br />
Resistance at<br />
20°C, (Ω/Km)<br />
</span></td>
</tr>
<tr class="row-2">
	<td class="column-6"><span> Single cable<br />
free in air (A)<br />
</span></td><td class="column-7"><span>Single cable<br />
on a surface (A)<br />
</span></td><td class="column-8"><span>Two loaded cables<br />
touching, on a surface (A)<br />
</span></td>
</tr>
<tr class="row-3">
	<td class="column-1">12010101xx01</td><td class="column-2">1.5</td><td class="column-3">0.70</td><td class="column-4">0.80</td><td class="column-5">4.66</td><td class="column-6">30</td><td class="column-7">29</td><td class="column-8">24</td><td class="column-9">13.7</td>
</tr>
<tr class="row-4">
	<td class="column-1">12010102xx01</td><td class="column-2">2.5</td><td class="column-3">0.70</td><td class="column-4">0.80</td><td class="column-5">5.09</td><td class="column-6">41</td><td class="column-7">39</td><td class="column-8">33</td><td class="column-9">8.21</td>
</tr>
<tr class="row-5">
	<td class="column-1">12010103xx01</td><td class="column-2">4.0</td><td class="column-3">0.70</td><td class="column-4">0.80</td><td class="column-5">5.59</td><td class="column-6">55</td><td class="column-7">52</td><td class="column-8">44</td><td class="column-9">5.09</td>
</tr>
<tr class="row-6">
	<td class="column-1">12010104xx01</td><td class="column-2">6.0</td><td class="column-3">0.70</td><td class="column-4">0.80</td><td class="column-5">6.13</td><td class="column-6">70</td><td class="column-7">67</td><td class="column-8">57</td><td class="column-9">3.39</td>
</tr>
<tr class="row-7">
	<td class="column-1">12010105xx01</td><td class="column-2">10.0</td><td class="column-3">0.70</td><td class="column-4">0.80</td><td class="column-5">7.07</td><td class="column-6">98</td><td class="column-7">93</td><td class="column-8">79</td><td class="column-9">1.95</td>
</tr>
<tr class="row-8">
	<td class="column-1">12010106xx01</td><td class="column-2">16.0</td><td class="column-3">0.70</td><td class="column-4">0.90</td><td class="column-5">8.32</td><td class="column-6">132</td><td class="column-7">125</td><td class="column-8">107</td><td class="column-9">1.24</td>
</tr>
<tr class="row-9">
	<td class="column-1">12010107xx01</td><td class="column-2">25.0</td><td class="column-3">0.90</td><td class="column-4">1.00</td><td class="column-5">10.14</td><td class="column-6">176</td><td class="column-7">167</td><td class="column-8">142</td><td class="column-9">0.795</td>
</tr>
<tr class="row-10">
	<td class="column-1">12010108xx01</td><td class="column-2">35.0</td><td class="column-3">0.90</td><td class="column-4">1.10</td><td class="column-5">11.49</td><td class="column-6">218</td><td class="column-7">207</td><td class="column-8">176</td><td class="column-9">0.565</td>
</tr>
<tr class="row-11">
	<td class="column-1">12010109xx01</td><td class="column-2">50.0</td><td class="column-3">1.00</td><td class="column-4">1.20</td><td class="column-5">13.33</td><td class="column-6">276</td><td class="column-7">262</td><td class="column-8">221</td><td class="column-9">0.393</td>
</tr>
<tr class="row-12">
	<td class="column-1">12010110xx01</td><td class="column-2">70.0</td><td class="column-3">1.10</td><td class="column-4">1.20</td><td class="column-5">15.19</td><td class="column-6">347</td><td class="column-7">330</td><td class="column-8">278</td><td class="column-9">0.277</td>
</tr>
<tr class="row-13">
	<td class="column-1">12010111xx01</td><td class="column-2">95.0</td><td class="column-3">1.10</td><td class="column-4">1.30</td><td class="column-5">16.94</td><td class="column-6">416</td><td class="column-7">395</td><td class="column-8">333</td><td class="column-9">0.210</td>
</tr>
<tr class="row-14">
	<td class="column-1">12010112xx01</td><td class="column-2">120.0</td><td class="column-3">1.20</td><td class="column-4">1.30</td><td class="column-5">18.71</td><td class="column-6">488</td><td class="column-7">464</td><td class="column-8">390</td><td class="column-9">0.164</td>
</tr>
<tr class="row-15">
	<td class="column-1">12010113xx01</td><td class="column-2">150.0</td><td class="column-3">1.40</td><td class="column-4">1.40</td><td class="column-5">20.86</td><td class="column-6">566</td><td class="column-7">538</td><td class="column-8">453</td><td class="column-9">0.132</td>
</tr>
<tr class="row-16">
	<td class="column-1">12010114xx01</td><td class="column-2">185.0</td><td class="column-3">1.60</td><td class="column-4">1.60</td><td class="column-5">23.24</td><td class="column-6">644</td><td class="column-7">612</td><td class="column-8">515</td><td class="column-9">0.108</td>
</tr>
<tr class="row-17">
	<td class="column-1">12010115xx01</td><td class="column-2">240.0</td><td class="column-3">1.70</td><td class="column-4">1.70</td><td class="column-5">26.14</td><td class="column-6">755</td><td class="column-7">736</td><td class="column-8">620</td><td class="column-9">0.0817</td>
</tr>
</tbody>
</table>

<p class="p-desc p-md custom-asterisk">*Construction Product Regulation (CPR) is a regulation issued by the European Union with the purpose of regulating the limits of fire resistance and dangerous substances in the materials used in construction. This regulation applies to all products intended to be incorporated, permanently, in construction. Above link provides the DOP (declaration of performance) for the CPR compliance for the product.)</p>
   
    </div>
</section><p>The post <a href="https://www.rrkabel.com/products/solar-cable-en-50618/">Solar Cable &#8211; EN 50618</a> appeared first on <a href="https://www.rrkabel.com">R R Kabel Limited</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
